LORIOT

LORIOT is the international LoRaWAN network of the first Smart Parks deployments. Smart Parks Protect connects to the application's websocket output and sends downlinks over the same connection (decision D54). Live verification against a LORIOT application is pending; the adapter is built from the LORIOT documentation and its fixtures are invented, see tests/fixtures/payloads/loriot/README.md.

Setup

  1. In LORIOT, open the application and add an output of type Websocket; copy its token.
  2. Server admin, Data sources, New data source, adapter LORIOT: server (for example eu1.loriot.io), app_id and web_url for deep links, credential token.
  3. The ingest service connects within a minute (connector started in its log) and reconnects after a drop.
  4. Register the DevEUIs as external identities, or accept them from Needs Attention.

LORIOT's HTTP output is accepted as well: point it at the source's webhook URL with the bearer token; the frames are the same JSON.

rx frames become uplink source events with data and port as the LoRaWAN frame, fcnt, data rate, RSSI and SNR as provider metadata; gw frames become gateway_receptions events holding every gateway that received the uplink. ts (milliseconds) is the network receive time.

A command opens a short-lived websocket to the application output, sends {"cmd":"tx","EUI","port","confirmed","data"} and reads LORIOT's tx answer: success with a sequence number moves the command to queued, an error fails it. txd with the same sequence number moves it to transmitted. The device's answer confirms it when the action has an interpreter.

Timestamps

ts is milliseconds since the epoch, stored as network_received_at. Device time comes from the OpenCollar frame.

Troubleshooting

  • The ingest log shows websocket lost, reconnecting in a loop: the token is wrong or the output was deleted in LORIOT.
  • No gw frames: enable gateway information on the LORIOT output.
  • CONNECTIVITY_UNAVAILABLE on a command: LORIOT did not answer the tx frame within 15 seconds; the bus retries the command action for automations, a person retries from the device page.